DeFelsko PosiTector SST

F.A.Q.


Why is salt contamination measurement important?

The presence of soluble salts has been shown to have a significant negative effect on coating performance and leads to premature coating failure. Salts remaining beneath a protective coating create an osmotic force that draws water from the atmosphere through the paint layer. The pressure created by this water underneath the coating overcomes the adhesive bond between the coating and substrate, resulting in corrosion, osmotic blistering and eventual coating failure. It is therefore critical to ensure that a substrate is free from soluble salt contamination before painting.

What is measured with the DeFelsko PosiTector SST?

The DeFelsko PosiTector SST includes a certified and traceable conductivity probe specifically designed for ISO 8502-6,9. Included with each probe is a Long Form Certificate of Calibration. The following parameters are measured by the DeFelsko PosiTector SST:

  • Conductivity (μS/cm)
  • Sampling Temperature (C° or F°) normalized to 25°C
  • Test duration

Using the measured conductivity value and the sample test volume (set within the gage menu), the surface density of the salts (mg/m2 or μg/cm2) is automatically calculated in accordance with ISO 8502-9, saving the gage operator time and eliminating the chance of a calculation error.

What are some typical applications?

The DeFelsko PosiTector SST is ideal for:

  • Testing substrates for the presence of soluble salts in accordance with ISO 8502-6,9 (the Bresle Method)
  • Testing blast media in accordance with ASTM 4940 and ISO 11127-6 (determination of water-soluble contaminates in abrasives by conductivity measurement)
  • Testing the conductivity of water within the range of 0-500 μS/cm

What information does the DeFelsko PosiTector SST save in its memory for each test?.

  • Date and time of test
  • Test duration (the total time of contact between the solvent and substrate)
  • Background sample temperature (°C or °F)
  • Final sample temperature (°C or °F)
  • Increase in conductivity between background and final sample (μS/cm)
  • Calculated surface density of soluble salts (mg NaCl/m2, mg CL/m2, μg NaCl/cm2, or μg Cl/cm2)

Do your instruments require any formal training for use? Do you offer ‘demo’ models?

No. Our instruments are designed for simple operation, feature easy-to-use menus, both full and quick instruction manuals, and helpful videos. In lieu of demonstration models, we provide unlimited technical support via telephone and/or email, and a limited 30-day money back guarantee.

Does the DeFelsko PosiTector SST need to be calibrated prior to use?

The DeFelsko PosiTector SST arrives fully calibrated and ready to measure. A Long-Form Certificate of Calibration traceable to NIST or PTB is included, which documents actual readings taken by your instrument at our calibration laboratory on standards traceable to a national metrology institute. Beware of ‘Certificates’ or ‘Certificates of Conformance’ offered by competitors. These typically do not include actual instrument readings, and are often insufficient to meet common quality requirements.A Verification of Accuracy can be performed by the user by measuring known reference standards such as the supplied conductivity standard.

Does the DeFelsko PosiTector SST measure the concentration of individual salt ions?

The DeFelsko PosiTector SST measures the overall conductivity of the test solution, and using calculations specified in ISO 8502-9, converts this value into a total surface density of salts.

Does the DeFelsko PosiTector SST display readings in PPM of salt?

The DeFelsko PosiTector SST is built specifically for the Bresle test method which does not address PPM calculations. While empirical conversion factors exist for converting PPM to surface density, these are not recognized by any test method.

Can the DeFelsko PosiTector SST probe be immersed in the fluid it is testing?

Yes. By immersing only the test cell, the DeFelsko PosiTector SST is ideal for testing the conductivity of water within the range of 0-500 μS/cm.

Can the DeFelsko PosiTector SST be used to measure the salt concentration in blast media?

Yes. The DeFelsko PosiTector SST can be used as a conventional conductivity meter making it ideal for testing abrasive materials in accordance with ISO 11127-6 and ASTM D4940-15.

How often should the PosiTector probe be recalibrated?

PosiTector probes include a Certificate of Calibration with no expiry or end date. They have no shelf life, therefore the length of time in the field is not a good indicator for recalibration intervals. Many organizations with quality programs and recertification programs require annual recalibrations, and this is a good starting point for most users. DeFelsko recommends that customers establish calibration intervals based upon their own experience and work environment. Based on our product knowledge, data and customer feedback, a one year calibration interval from the date the instrument was placed in service is a good starting point.

DeFelsko SSTKITL1 PosiTector SST Soluble Salt Tester Latex Patch Standard Kit

$1,070.00
FREE 2-Day Shipping
About this item
  • DeFelsko SSTKITL1 PosiTector SST Soluble Salt Tester Latex Patch Standard Kit with PosiTector Standard Gage Body, PosiTector SST Probe, Latex Adhesive Patch (25), Syringe and Needle (2), 250 ml DI Water, Cup (5), Hard-shell Carrying Case
  • Conductivity probe specifically designed for ISO 8502-6,9
  • Solvent, acid, oil, water and dust resistant – weatherproof

View More Details

DeFelsko SSTKITL3 PosiTector SST Soluble Salt Tester Latex Patch Advanced Kit

$1,535.00
FREE 2-Day Shipping
About this item
  • DeFelsko SSTKITL3 PosiTector SST Soluble Salt Tester Latex Patch Advanced Kit with PosiTector Advanced Gage Body, PosiTector SST Probe, Latex Adhesive Patch (25), Syringe and Needle (2), 250 ml DI Water, Cup (5), Hard-shell Carrying Case
  • Conductivity probe specifically designed for ISO 8502-6,9
  • Solvent, acid, oil, water and dust resistant – weatherproof

View More Details

DeFelsko SSTKITL PosiTector SST Soluble Salt Tester Latex Patch Kit and Probe On...

$745.00
FREE 2-Day Shipping
About this item
  • DeFelsko SSTKITL PosiTector SST Soluble Salt Tester Latex Patch Kit & Probe Only with PosiTector SST, Latex Adhesive Patch (25), Syringe and Needle (2), 250 ml DI Water, Cup (5) (Gauge not Included)
  • Conductivity probe specifically designed for ISO 8502-6,9
  • Solvent, acid, oil, water and dust resistant – weatherproof

View More Details

DeFelsko SSTABRKIT PosiTector SST Abrasives Test Kit

$490.00
FREE 2-Day Shipping
About this item
  • DeFelsko SSTABRKIT PosiTector SST Abrasives Test Kit
  • Measures the concentration of water-soluble contaminates in blast cleaning abrasives
  • Quickly test abrasives for soluble salt contamination in the field or in the laboratory

View More Details

DeFelsko PosiTector SST Bresle Method Patches

$100.00 - $305.00
About this item
  • Reusable patches with Standard or Flexible magnetic ring
  • For measuring salt contamination in accordance with ISO 8502-6,9
  • Magnetic ring attaches to steel with no residue to clean

View More Details

DeFelsko PosiTest DT Dust Tape Test

$145.00 - $325.00
About this item
  • Assesses the quantity and size of dust particles on blast cleaned surfaces in accordance with ISO 8502-3
  • Conforms to ISO 8502-3, AS 3894.6, US Navy PPI 63101-000

View More Details

Paint Test Equipment Bresle Chloride Test Kit with Certificates

$659.00
FREE Ground Shipping
About this item
  • Bresle Test is supplied in an industrial Carrying Case with Bresle Patches (pack of 35), Horiba Conductivity Meter, Deionised Water (500ml), Syringe with Needle, 1413?S/cm Calibration Solution (14ml), Conditioning Solution (14ml) and Beaker.
  • This Chloride Test on steel or Salt Test on steel using the Bresle Patch or Bresle Sampler method will help to prevent coating failure due to salts such as chlorides and sulphates contaminating the surface prior to the coating application.

View More Details


Copyright © 2025 Abq Industrial