Wall Thickness Gauge Accessories
F.A.Q.
How do I choose between CF-4 / CF-12, CF-4H (Sono 600), and CF-4H-950F ultrasonic couplants?
Select your ultrasonic coupling fluid based on the surface temperature of the material being inspected:- For ambient and warm assets from 0°F to 200°F (-18°C to 93°C), use standard Dakota CF-4 or Dakota CF-12 (
Soundsafe) couplant. - For hot in-service piping and vessels between 200°F and 700°F (93°C to 371°C), standard couplant will boil or evaporate immediately—use CF-4H High Temperature Coupling Fluid Sono 600.
- For extreme thermal surfaces from 600°F up to 950°F (316°C to 510°C), use CF-4H-950F High Temperature Coupling Fluid.
Why should I use a multi-step calibration test block instead of only the built-in zero disc?
The circular metal disc mounted on the housing of an ultrasonic gauge is a Probe Zero Plate designed solely to compensate for the transducer's internal delay wedge (Zero Set)—its thickness is not intended for sound velocity calibration across a wide measuring range. A precision 4-Step, 5-Step, or 6-Step Calibration Block allows you to perform a 2-Point Calibration on both a thin step (near your minimum expected reading) and a thick step (near your maximum expected reading), calibrating both zero offset and material sound velocity simultaneously.
When do I need a certified vs. uncertified ultrasonic step test block?
If your facility operates under ISO 9001, API, ASME, aerospace, or nuclear quality management programs that require documented traceability, select our certified Dakota Calibration Blocks or add the optional NIST Traceable (
NISTCAL) or ISO-17025 (ISO-17025-SB) calibration certificate to our Uncertified Steel Test Blocks. For routine internal maintenance checks where formal audit paperwork is not required, uncertified step blocks provide the exact same machined steps at a lower cost.DataComm Software
Call for Price
About this item
View More Details
- Data Transfer & Analysis Program For Datalogging Wall Thickness Gauges
- Free Download
- Manufacturer: Checkline
View More Details
Dakota Ultrasonics T-101-3300CPZT-S Transducer
Discontinued Product
About this item
View More Details
- Dakota Ultrasonics T-101-3300CPZT-S Transducer
- 3/16" diameter, 7.5 MHz Composite Probe with dual microdot connectors
- Top-in cable with 1 inch extension "snout"
- Manufacturer: Dakota Ultrasonics
View More Details
Copyright © 2026 Abq Industrial