$1,241.00
    warranty 1 year
    Product Description
    -2.000 to 20.000 pH range
    0.1, 0.01, & 0.001 pH resolutions
    USA, NIST, NIST2, DIN, and Custom pH buffer groups


          
     

    Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter
    Compact and Powerful

    The Horiba 3200912574 Laqua PC2000 Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter Compact and Powerful is a water quality analysis is repeatedly performed in laboratories on a daily basis. Our compact and powerful benchtop model was developed to provide simplicity with excellent on-site usability.

    Kit Contents


    • Horiba 3200912574 Laqua PC2000 Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter Compact and Powerful
    • Electrode Stand
    • Universal power adaptor with 6 plugs (US, EU, UK, ANZ, Korea, China)
    • Instruction Manual
    Click image to enlarge

    Features


    • Up to 2.000 S/cm conductivity range
    • Adjustable reference temperature: 15 to 30 °C
    • Adjustable temperature coefficient: 0.00 to 10.00 % per °C
    • Accepts 0.0700 to 13.000 cell constant
    • Allows auto and manual conductivity calibrations
    • Up to 5 conductivity calibration points
    • Auto ranging S/cm and S/m conductivity units
    • 0.01 mg/L to 100 g/L TDS range
    • Pre-programmed TDS curves: Linear (0.40 to 1.00 TDS factor), EN27888, 442, & NaCl
    • 0.000 Ω•cm to 20.0 MΩ•cm resistivity range
    • 0.0 to 100.0 ppt and 0.00 to 10.00 % salinity ranges
    • Pre-programmed salinity curves: NaCl and seawater
    • -30.0 to 130.0°C / -22.0 to 266.0°F temperature range with calibration option
    • Auto stable, auto hold, and real time measurement modes
    • Electrode status, temperature, and reading stability indicators viewable at a glance
    • Large memory accepting up to 2000 data sets with date/time stamp
    • Auto data log function with adjustable time interval
    • Real time clock facilitating time-dependent functions
    • Adjustable auto shut-off time up to 30 mins.
    • Password protected set-up mode for security
    • Software upgrade capability
    • PC communication via USB cable and complimentary data acquisition software
    • Printer communication via RS232 cable
    • 5” Digital, custom LCD display with backlight
    • Sleek design with easy-to-use interface and audible key sound feedback
    • Small meter footprint with adjustable, integrated electrode stand
    • 3 Years warranty

    Specifications


    pH Range-2.000 to 20.000 pH
    Resolution0.1 / 0.01 / 0.001 pH
    Accuracy± 0.003 pH
    pH Buffer GroupsUSA, NIST, NIST2, DIN, Custom
    Calibration PointsUp to 5 (USA, NIST, NIST2, Custom) / Up to 6 (DIN)
    ORP Range± 2000.0 mV
    Resolution0.1 mV
    Accuracy± 0.2 mV 
    Calibration OptionYes (Up to ± 200 mV)
    Ion Range0.000 µg/L to 9999 g/L
    Units µg/L ↔ mg/L ↔ g/L, ppm ↔ ppt, mmol/L ↔ mol/L
    Resolution4 Significant digits
    Accuracy± 0.3% full scale or ± 0.2 mV, whichever is higher
    Calibration PointsUp to 5 
    Conductivity Range0.000 to 1.999 µS/cm (k = 0.1)
    2.00 to 19.99 µS/cm (k = 0.1, 1)
    20.0 to 199.9 µS/cm (k = 0.1, 1, 10)
    200 to 1999 µS/cm (k = 0.1, 1, 10)
    2.00 to 19.99 mS/cm (k = 0.1, 1, 10)
    20.0 to 199.9 mS/cm (k = 1, 10)
    0.200 to 2.000 S/cm (k = 10)
    UnitsAuto ranging S/cm, S/m (µS ↔ mS ↔ S)
    Resolution0.05% full scale
    Accuracy± 0.6% full scale; ± 1.5% full scale > 18.0 mS/cm
    Reference Temperature15.0 to 30.0 °C (adjustable)
    Temperature Coefficient0.00 to 10.00 % per °C (adjustable)
    Cell Constants0.070 to 13.00 (adjustable)
    Calibration PointsUp to 4 (Auto) / Up to 5 (Manual)
    Resistivity Range0.001 MΩ・cm to 20.0 MΩ・cm
    Resolution0.5% full scale
    Accuracy± 0.6% full scale; ± 1.5% full scale > 1.80 MΩ●cm
    Total Dissolved Solids (TDS) Range0.01 to 9.99 mg/L (ppm)
    10.0 to 99.9 mg/L (ppm)
    100 to 999 mg/L (ppm)
    1.00 to 9.99 g/L (ppt)
    10.0 to 100 g/L (ppt)
    Resolution0.01, 0.1, 1 mg/L ↔ g/L (ppm ↔ ppt)
    Accuracy± 0.1% full scale
    TDS CurvesEN27888, 442, NaCl, Linear (0.40 to 1.00)
    Salinity Range0.0 to 100.0 ppt / 0.00 to 10.00 %
    Resolution0.1 ppt / 0.01%
    Accuracy± 0.2% full scale
    Salinity CurvesNaCl / Seawater
    Calibration OptionYes (Manual; 1 point)
    Temperature Range-30.0 to 130.0 °C / -22.0 to 266.0 °F
    Resolution0.1 °C / °F
    Accuracy± 0.5 °C / ± 0.9 °F
    Calibration OptionYes (± 10.0 °C / ± 18.0 °F range in 0.1 °C increments)
    Memory2000
    Auto Data LogYes
    Real-time ClockYes
    Date & Time StampYes
    Measurement ModesAuto Stable / Auto Hold / Real Time
    Offset & Slope DisplayYes (Segment & Average Slopes)
    Calibration Alarm Yes (Programmable: up to 90 days)
    Auto Shut-Off Yes (Programmable: up to 30 mins.)
    Electrode StatusOn screen display
    DiagnosticsYes
    Password SettingYes
    Software UpgradeYes
    PC / Printer CommunicationPhono jack (USB / RS232C)
    Meter Inputs2 x BNC, 2 x phono (ATC), DC sockets
    Display5" Custom LCD with backlight and 320 segments
    Power RequirementAC adaptor 100 - 240V, 50 - 60Hz
    Dimensions & Weight155(L) x 150(W) x 67(H) mm, 770g