PosiTector 6000 Coating Thickness Gauges

Price: $625.00 up to $1,675.00
DeFelsko Positector 6000 Coating Thickness Gauges are simple and durable precision instruments that use magnetic and eddy current principles to accurately measure coating thickness on both ferrous and non-ferrous metals
A variety of different PosiTector 6000 model configurations are available to measure coating thickness on only ferrous, only non-ferrous or both ferrous and non-ferrous metals
The PosiTector 6000 Coating Thickness Gauges conform to ISO 2178/2360/2808, PrEN ISO 19840, ASTM B499/D1186/D1400/D7091/E376/G12, BS3900-C5, SSPC-PA2 and others.
All PosiTector 6000 Coating Thickness Gauges models come with 2-year Warranty

Gauge body universally accepts all PosiTector 6000 (coating thickness), 200 (ultrasonic coating thickness), SPG (surface profile), DPM (environmental) and UTG (ultrasonic wall thickness) probes

line
Features
line

  • NIST Traceable calibration certificate included
  • Keypad-selectable units of measure; Mils, Microns, MM
  • Large high contrast backlit display
  • Keypad-selectable languages: English, Spanish, French, German, Portuguese and Italian
  • Solvent, acid, oil, water and dust resistant
  • The Positector 6000 Coating Thickness Gauges comes with 2-year warranty

line
Ordering Guide
line

Applications

Positector 6000 coating thickness gauge with built-in probe Positector 6000 coating thickness gauge with regular separate probe
Our most popular built-in and separate probe models
Non-magnetic coatings on FERROUS metals
(Steel & Cast Iron)
F1
F2
F3
FS1
FS2
FS3
Non-conductive coatings on NON-FERROUS metals (Aluminum, Copper, etc.) N1
N2
N3
NS1
NS2
NS3
Combination -
ALL METALS
FN1
FN2
FN3
FNS1
FNS2
FNS3
Measuring
Range

0 - 60 mils

0 - 1500 um
Accuracy** + (0.05 mils + 1%) 0 - 2 mils
+ (0.1 mils + 1%) > 2 mils
+ (1 um + 1%) 0 - 50 um
+ (2 um + 1%) > 50 um

line

Applications

Positector 6000 coating thickness gauge with regular separate probe positector 6000 coating thickness gauge with microprobe
Ideal for anodized aluminum Microprobes - Our smallest probes for small parts or hard-to-reach areas
Non-magnetic coatings on FERROUS metals
(Steel & Cast Iron)

F0S1
F0S2
F0S3
Non-conductive coatings on NON-FERROUS metals (Aluminum, Copper, etc.) NAS1
NAS2
NAS3
N0S1
N0S2
N0S3
Measuring
Range
0 - 25 mils
0 - 625 um
Accuracy** + (0.02 mils + 1%) 0 - 4 mils
+ (0.1 mils + 3%) > 4 mils
+ (1 um + 1%) 0 - 100 um
+ (2 um + 3%) > 100 um

line

Applications

Positector 6000 coating thickness gauge with built-in probe positector 6000 coating thickness gauge for thick coatings positector 6000 coating thickness gauge for thick coatings
High-range probes for very thick protective coatings on All Metals
Non-magnetic coatings on FERROUS metals
(Steel & Cast Iron)
FT1
FT2
FT3
FTS1
FTS2
FTS3
FKS1
FKS2
FKS3
Non-conductive coatings on NON-FERROUS metals (Aluminum, Copper, etc.)

NKS1
NKS2
NKS3
Combination -
ALL METALS

FNTS1
FNTS2
FNTS3

Measuring
Range
0 - 250 mils 0 - 500 mils
0 - 6 mm 0 - 13 mm
Accuracy** +( 0.5 mils + 1%) 0 - 100 mils
+( 0.5 mils + 3%) > 100 mils
+ (1 mil + 1%)
0 - 250 mils
+ (1 mil + 5%)
> 250 mils
+ (0.01 mm + 1%) 0 - 2.5 mm
+( 0.01 mm + 3%) > 2.5 mm
+ (0.02 mm + 1%)
0 - 6 mm
+ (0.02 mm + 5%)
> 6 mm

* Other models available. Please view PDF data sheet below  for complete ordering guide.
** Accuracies are stated as a fixed value plus a percentage of the gauges actual reading.
*** Check with us for the recommended calibration standards for each model of gauge.

line
DeFelsko Positector 6000 Models Comparison
line

Positector 6000 Basic (1) Models

  • No Calibration required for most applications
  • Mils / Microns switchable
  • Average ZERO feature: ideal for zeroing on rough surfaces
  • Indicator light: essential in a noisy environment to confirm a reading has been taken
  • Reversible display
  • RESET feature instantly restores factory settings
  • 2-Year warranty

Positector 6000 Memory (3) Models
All Basic (1) and Standard (2) Gauge Features plus...

  • Storage of 10,000 readings in up to 1000 batches-stored readings can be sub-grouped, viewed, updated or deleted
  • Built-in clock to date and time stamp each stored measurement
  • SSPC PA-2 feature determines if film thickness over a large area conforms to user-specified min/max levels
  • Multiple stored calibration adjustments for measuring on a variety of substrate conditions
  • Supplied with PosiSoft software and USB cable

line
Complete Kit
line

All Positector 6000 are supplied complete with precision plastic shims, protective rubber holster with belt clip, 3 AAA batteries, instructions, wrist strap (built-in style only), nylon carrying case with shoulder strap, NIST Traceable Certificate of Calibration, two (2) year warranty.

Memory (3) gauges also include PosiSoft Windows-based Analysis Software, USB cable.