<?xml version="1.0" encoding="utf-8"?>
<?xml-stylesheet type="text/css" href="https://www.abqindustrial.net/store/includes/templates/classic/css/rss.css" media="screen"?>
<!-- generator="Zen-Cart RSS Feed/"v 2.1.4 14.02.2008 15:26 -->
<rss version="2.0" 
xmlns:g="http://base.google.com/ns/1.0"
xmlns:c="http://base.google.com/cns/1.0"
xmlns:abq="http://www.abqindustrial.net"
xmlns:atom="http://www.w3.org/2005/Atom">
  <channel>
    <title>Albuquerque Industrial : RSS Product Feed :: Checkline F-1101-30 Foil Dial Thickness Gauge</title>
    <link>https://www.abqindustrial.net/store</link>
    <description>We offer an extensive line of precision measuring and test instrumentation. We	continually strive to offer unparalleled VALUE &amp;amp; QUALITY product and	service to our valued customers.</description>
    <atom:link href="https://www.abqindustrial.net/store" rel="self" type="application/rss+xml" />
    <language>en</language>
    <copyright>Copyright (c) 2026 Albuquerque Industrial</copyright>
    <managingEditor>info@abqindustrial.net (admin)</managingEditor>
    <webMaster>info@abqindustrial.net (admin)</webMaster>
    <lastBuildDate>Mon, 08 Jun 2026 20:47:57 +0000</lastBuildDate>
    <generator>Zen-Cart v. v 2.1.4 14.02.2008 15:26 RSS 2.0 Feed</generator>
    <ttl>1440</ttl>
    <item>
      <title>Checkline F-1101-30 Foil Dial Thickness Gauge</title>
      <link>https://www.abqindustrial.net/store/dial-thickness-gauges-c-57/checkline-f-1101-30-foil-dial-thickness-gauge-p-705.html</link>
      <comments>https://www.abqindustrial.net/store/index.php?main_page=product_reviews&amp;products_id=705</comments>
      <description>Resolution: 0.001 mm (1 µm) Measuring range: 1 mmAccuracy: ± 3 µmDepth of jaw: 30mmThe Checkline F-1101-30 Foil Dial Thickness Gauge is used exclusively to measure the thickness of foils. The frame has the required rigidity, the insulation of the handle prevents transfer of heat from the hand of the user to the sensitive mechanical parts of the Dial Gauge. One revolution of the pointer equals 0,1 mm. Because of the 100 divisions on the scale the measuring result can be more easily and more accurately read off then on the predecessor model F 1000/30. The applied pressure is approximately 2 N. 
Features
Special purpose model with resolution of 0.001 mm (1 µm)Operating by lifting device - self closingInsulated handle prevents transfer of heat from the hand of the user to the sensitive mechanical parts of the Dial Gauge
Specifications
Resolution0.001 mm Measuring range1 mm Accuracy± 3 µm Depth of jaw30 mm Scale diameter58 mm Measuring pressure2.0 N (On request: 0.7 N) Scale1 revolution = 0.1 mm Feeler shapeF - 6.35 mm Ø flat Measurment by spring loadOperating by lifting device - self closing Warranty1 year 
Feeler Shape
Feeler: Fsheet metal, glass, round material</description>
      <author>Albuquerque Industrial</author>
      <enclosure url="https://www.abqindustrial.net/store/images//products/F-1101-30/main_small.jpg" length="38665" type="image/jpeg" />
      <guid isPermaLink="true">https://www.abqindustrial.net/store/dial-thickness-gauges-c-57/checkline-f-1101-30-foil-dial-thickness-gauge-p-705.html</guid>
      <pubDate>Tue, 21 Apr 2026 14:28:40 +0000</pubDate>
      <g:currency>USD</g:currency>
      <g:id>705</g:id>
      <g:brand>Hans-Schmidt</g:brand>
      <g:quantity>999</g:quantity>
      <g:model_number>F-1101-30</g:model_number>
      <g:image_link>https://www.abqindustrial.net/store/images/products/F-1101-30/main_small.jpg</g:image_link>
      <abq:additional_image>https://www.abqindustrial.net/store/images/additional/f-1101-30-foil-dial-thickness-gauge-184.jpg</abq:additional_image>
      <abq:meta type="product_id" id="705">705</abq:meta>
      <abq:meta type="title" id="705"><![CDATA[F-1101-30 Foil Dial Thickness Gauge]]></abq:meta>
      <abq:meta type="keyword" id="705"><![CDATA[F-1101-30 Foil Dial Thickness Gauge]]></abq:meta>
      <abq:meta type="description" id="705"><![CDATA[F-1101-30 Foil Dial Thickness Gauge]]></abq:meta>
      <abq:products_summary><![CDATA[ The F-1101-30 Foil Dial Thickness Gauge is used exclusively to measure the thickness of foils. The frame has the required rigidity, the insulation of the handle prevents transfer of heat from the hand of the user to the sensitive mechanical parts of the Dial Gauge. One revolution of the pointer equals 0,1 mm. Because of the 100 divisions on the scale the measuring result can be more easily and more accurately read off then on the predecessor model F 1000/30. ]]></abq:products_summary>
      <abq:category type="category" id="57"><![CDATA[Dial Thickness Gauges]]></abq:category>
      <abq:attribute type="name" id="1221" products_type="2"><![CDATA[F-1101-30 Foil Thickness Gauge - Model]]></abq:attribute>
      <abq:attribute type="value" parent_id="1221" id="4101" price="0" weight="0" mpn="" manufactor="Hans-Schmidt" google_product_type="Hardware &amp;gt; Tools &amp;gt; Measuring Tools &amp; Sensors &amp;gt; Dial Thickness Gauges" ordered="0"><![CDATA[None]]></abq:attribute>
      <abq:attribute type="value" parent_id="1221" id="4102" price="644" weight="3" mpn="F-1101-30" manufactor="Hans-Schmidt" google_product_type="Hardware &amp;gt; Tools &amp;gt; Measuring Tools &amp; Sensors &amp;gt; Dial Thickness Gauges" ordered="0"><![CDATA[Checkline F-1101-30 Dial Foil Thickness Gauge, Measuring Range 0.001 mm]]></abq:attribute>
      <abq:total_ordered>1</abq:total_ordered>
      <abq:warranty_image>/store/images/warranty-1-year-new.png</abq:warranty_image>
      <abq:main_feature><![CDATA[ &lt;hr /&gt;&lt;p&gt;Resolution: 0.001 mm (1 µm) &lt;/p&gt;&lt;hr /&gt;Measuring range: 1 mm&lt;hr /&gt;Accuracy: ± 3 µm&lt;hr /&gt;Depth of jaw: 30mm&lt;hr /&gt; ]]></abq:main_feature>
    </item>
  </channel>
</rss>
